Control Robusto del Convertidor CD/CD Reductor Paralelo-Cascada (On The Robust Control of Parallel-Cascade DC/DC Buck Converter)

Esteban Guerrero (egerrero@mixteco.utm.mx)2, Hebbert Sira (hsira@cinvestav.mx)1, Alberto Martínez (alberto.mtba@gmail.com)2, Jesús Linares (jlinares@mixteco.utm.mx)2, Enrique Guzmán (eguzman@mixteco.utm.mx)2


1Cinvestav-IPN
2Universidad Tecnológica de la Mixteca

This paper appears in: Revista IEEE América Latina

Publication Date: Feb. 2016
Volume: 14,   Issue: 2 
ISSN: 1548-0992


Abstract:
This paper presents the design and simulation of robust control for DC/DC multi-converter based on terms like differential flatness and active disturbance rejection. The main goal of the control law is to obtain a regulated output voltage for each converter in cascade, and a balance of currents for parallel converters. The controller must actively reject the endogenous and exogenous disturbances, i.e. maintaining a robust output. The effectiveness of the proposed controller was verified by computer simulations using MATLAB/Simulink.

Index Terms:
Differential Flatness, Disturbance Active Rejection, GPI Observers, DC/DC Buck Converter, Non-linear systems.   