Treatment of all matters relating to high voltage power circuit breakers (above 1000 Volts AC and 3200 Volts DC).
Chairman: Rod Sauls
Southern Company Services
Spring 2012 - Roy Alexander - Capacitor Switching - Energy Balance Approach, testing of 72 kV SF6 breakers, prestrikes and restrikes.
Standards covered
by this subcommittee and their
status
| 1325 | IEEE Recommended Practice for Reporting Field Failure Data for Power Circuit Breakers | W. Bergmann/D. Sharma | Will be withdrawn upon approval of C37.10 |
| C37.04 | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis | J. Nelson | PAR submitted. Major revision which will also include addition of C37.04a, .04b, .06 and NEMA SG4 |
| C37.04a | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis---Amendment 1: Capacitance Current Switching | R. Alexander | R2006; To be included in C37.04 |
| C37.04b | IEEE Standard Rating Structure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis---Amendment 1: TRV Descriptions (Harmonized with to IEC 62271-100) | K. Smith | Active C37.04b-2008. Will be included in C37.04 |
| C37.06 | American National Standard for Switchgear--AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis--Preferred Ratings and Related Required Capabilities | G. Montillet | Active C37.06-2009 |
| PC37.06.1 | Draft Recommended Practice for Preferred Ratings for High Voltage (> 1000V) AC Circuit Breakers Designated Definite Purpose for Fast Transient Recovery Voltage Rise Times | Keith Wallace | 2000 version currently under revision. |
| C37.09 | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis | TBD | R2007; Corr 1 & Errata Pub 2007 |
| C37.09a | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis---Amendment 1: Capacitance Current Switching | R. Alexander | Active C37.09a-2005; R2007 |
| C37.09b | IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis---Amendment 1: TRV Descriptions (Harmonized with to IEC 62271-100) | K. Smith | Active C37.09b-2010 |
| PC37.010 | Draft IEEE Application Guide for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis | H. Heiermeier | Currently under revision |
| PC37.011 | Draft IEEE Application Guide for Transient Recovery Voltage for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis | D. Dufournet | Submitted to RevCom, waiting for review |
| PC37.012 | Draft IEEE Application Guide for Capacitance Current Switching for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis | A. Bosma | PAR Approved. Currently under revision |
| PC37.013 PP62271-37-013 | Draft IEEE Standard for AC High-Voltage (rated above 1000 V)
Generator Circuit Breakers for Use with Generators Rated 10 MVA or More
|
W. Long | Joint IEEE/IEC document currently under revision |
| C37.013a | Standard for AC High Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis – Amendment 1: Supplement for use with Generators Rated 10-100 MVA | W. Long | Active C37.013a-2007. Will be included in .013 revision. |
| C37.015 | IEEE Application Guide for Shunt Reactor Switching | A. Bosma | Active C37.015-2009 |
| C37.016 | Standard for AC High-Voltage Circuit Switchers rated 15 kV through 245 kV | P. Meyer | Active C37.016-2006 |
| C37.017 | Standard for Bushings for High Voltage (over 1000 V ac) Circuit Breakers and Gas Insulated Switchgear | D. Sharma | Active C37.017-2010 |
| C37.081 | IEEE Guide for Synthetic Fault Testing of AC High-Voltage Circuit Breakers Rated on a Symmetrical Current basis | TBD | R2007 |
| C37.081a | Supplement to C37.081-1981 | TBD | R2007 |
| C37.082 P62271-37-082 | IEEE Standard Methods for the Measurement of Sound Pressure Levels of AC Power Circuit Breakers | L. Falkingham | PAR Approved. Currently under revision |
| C37.083 | IEEE Guide to Synthetic Capacity Current Switching Test of AC High-Voltage Circuit Breakers | TBD | R2007 |
| PC37.10 | Draft IEEE Guide for Diagnostics and Failure Investigation of Power Circuit Breakers | W. Bergman | R2008; D4 Balloted in April 2011; Will include IEEE 1325 |
| C37.10.1 | IEEE Guide for the Selection of Monitoring for Circuit Breakers | W. Bergman | Reaffirmation ballot to be sent before end of 2011 |
| PC37.11 | Draft IEEE Standard Requirements for Electrical Control for High-Voltage Circuit Breakers Rated on A Symmetrical Current Basis | John Webb | Currently under revision |
| C37.12 | IEEE Standard for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis | K. Edwards / D.Sharma | Active C37.12-2008 |
| C37.12.1 | IEEE Guide for High Voltage (>1000 V) Circuit Breaker Instruction Manual Content | W. Bergman | Active C37.12.1-2007 |
| C37.20.6 | 4.76kV to 38 kV Rated Grounding and Testing devices used in Enclosures (in cooperation with the Switchgear Assemblies Subcommittee) | Ted Burse | Active C37.20.6-2007 |