Corner

High Voltage Switches Subcommittee


Scope

Treatment of all matters relating to indoor and outdoor switches and interrupters rated above 1000 V ac and 3200 V dc except for the following devices:

  1. Distribution cutouts.
  2. Switches used in metal-enclosed and pad-mounted switchgear.
  3. Separable insulated connectors.
  4. Circuit-breakers, circuit-switchers, sectionalizers and reclosers.
  5. Gas-insulated switchgear.
  6. Capacitor switches.
  7. Switches rated 38 kV ac and below used on distribution systems except air insulated overhead applications.
  8. Fuses equipped with integral switches.


Chairman:

Carl Reigart

Hubbell Power Systems/USCO
CReigart@hubbell.com


Vice-Chair / Secretary:

James Houston

Southern Company
JEHousto@southernco.com



What's new in C37.30.1TM-2011?


  1. C37.30.1TM-2011 now references C37.100.1TM-2007, IEEE Standard of Common Requirements for High Voltage Power Switchgear Rated Above 1000 V, Annex B, (normative) Altitude correction factors. For users of C37.30.1TM-2011 it is important to recognize that this Common Requirement supersedes all previous altitude corrections and is more stringent than previously utilized information.
  2. A tutorial on C37.30.1TM-2011, Annex C, (informative) Application conditions for continuous load current capability. This tutorial is intended to increase understanding of ACCC designations and applications.


Subcommittee Documents, Working Groups, and Task Forces:

Document Title Chairperson Activity Status*
C37.30.1 IEEE Standard Requirements for AC High-Voltage Air Switches Rated Above 1000 V Ken Harless Active PAR Expires: 12/31/2018
Ballot Date:
Completion:
C37.30.1a Amendment to IEEE Standard Requirements for AC High-Voltage Air Switches Rated Above 1000 V Carl Reigart Active PAR Expires: 12/31/2019
Ballot Date:
Completion:
C37.30.2 IEEE Guide for Wind Loading Evaluation of High Voltage (>1000 V) Air Break Switches James Houston Inactive New WG:
Approved: 9/3/2015
Expires: 9/3/2025
Published
C37.30.3 IEEE Standard for Requirements for Interrupter Switches, Interrupters or Interrupting Aids Used on or Attached to Switches Rated for High-Voltage AC Above 1000 Volts Danny Hoss Active PAR Expires: 12/31/2016
Ballot Date:
Completion:
C37.30.4 IEEE Standard Requirements for Test Code for Switching and Fault Making Tests for High Voltage Interrupter Switches, Interrupters or Interrupting Aids Used on or Attached to Switches Rated for High-Voltage AC Above 1000 Volts Bill Hurst Active PAR Expires: 12/31/2016
Ballot Date:
Completion:
C37.30.5 IEEE Standard for Definitions for AC High-Voltage Air Switches Rated Above 1000 V Carl Reigart Active PAR Expires: 12/31/2019
Ballot Date:
Completion:

                 * All future dates are expected dates.


                 For more information on the HVS Subcommittee please see the Minutes of the Meetings.